Various cookies are used on our website: We use technically necessary cookies for the purpose of enabling functions such as login or a shopping cart. We use optional cookies for marketing and optimization purposes, in particular to place relevant and interesting ads for you on Meta's platforms (Facebook, Instagram). You can refuse optional cookies. More information on data collection and processing can be found in our privacy policy.
Ihre exklusive Workshopreihe 202229. Apr 2022 — 23. Nov 2022Seminarzentrum Schwarzheide, Schwarzheide, Germany
Speakers: Robert Böttcher, Daniel H.-J. Edelhoff, Claus-Peter Ernst, Tom Friedrichs, Jochen Peters, Peter Pospiech, Bernd Wöstmann
Dentallabor Gürtler
Deutscher Zahnärztetag 2019
8. Nov 2019 — 9. Nov 2019Congress Center Messe Frankfurt
Speakers: Karl-Ludwig Ackermann, Sarah Al-Maawi, Kurt Werner Alt, Jassin Arnold, Thomas Attin, Mustafa Ayna, Anna Greta Barbe, Ingo Baresel, Jens Baresel, Tobias Bauer, Ursula Becker, Wilfried Beckmann, Christoph Benz, Lisa Bitterich, Dirk Bleiel, Uwe Blunck, Martin Boost, Andreas Braun, Anne Bredel-Geissler, Wolfgang Buchalla, Egon Burian, Sebastian Bürklein, Iain L. C. Chapple, Wolfgang Christian, Fabian Cieplik, Bettina Dannewitz, Monika Daubländer, Sybille David-Hebgen, Isabel Deckwer, James Deschner, Annika Döding, Christof Dörfer, Heike Dyrna, Norbert Engel, Peter Engel, Susanne Fath, Michael Frank, Roland Frankenberger, Rene Franzen, Cornelia Frese, Tobias Fretwurst, Michael Gahlert, Roland Garve, Werner Geurtsen, Shahram Ghanaati, Christiane Gleissner, Ulrike Gonder, Werner Götz, Dominik Groß, Knut A. Grötz, Martin Guffart, Norbert Gutknecht, Cornelius Haffner, Thorsten Halling, Frederic Hermann, Carlos Herrera-Vizcaino, Tim Hilgenfeld, Jürgen Hoffmann, Martin Hoffmann, Fabian Huettig, Alfons Hugger, Christine Hutschenreuter, Bruno Imhoff, Silke Jacker-Guhr, Søren Jepsen, A. Rainer Jordan, Alexander Jürchott, Bärbel Kahl-Nieke, Peer W. Kämmerer, Philipp Kanzow, Nele Kettler, Christian Kirschneck, Lydia Kogler, Bernd Kordaß, Franz-Josef Kramer, Norbert Krämer, Felix Krause, Matthis Krischel, Joachim Krois, Christina Kühne, Conrad Kühnöl, Bernd Lapatki, Silke Lehmann-Binder M.Sc., Christian Leonhardt, Ivona Leventic, Daniel Lindel, Jörg Alexander Lisson, Ulrike Lübbert, Elmar Ludwig, Anne-Katrin Lührs, Michael Lüpke, Frank Georg Mathers, Wibke Merten, Georg Meyer, Wolfram Misselwitz, Karin Mölling, Mhd Said Mourad, Dietmar Friedrich Müller, Moritz Mutschler, Katja Nickel, Nicole Nicklisch, Ina Nitschke, Olaf Oberhofer, Karina Obreja, Dietmar Oesterreich, Rebecca Otto, Simon Peroz, Peter Pospiech, Florian Probst, Monika Probst, Michael Rädel, Sven Reich, Katharina Reichenmiller, Katharina Reinecke, Daniel R. Reißmann, Bernd Reiss, Stefan Ries, Christiane Rinnen, Katharina Röher, Jerome Rotgans, Uwe Rudol, Sebastian Ruge, Michael Rumpf, Heidrun Schaaf, Claudia Schaller, Karina Schick, Ulrich Schiffner, Maximiliane Amelie Schlenz, Alexander Schmidt, Mathias Schmidt, Andrea-Maria Schmidt-Westhausen, Julian Schmoeckel, Wolfgang Schneider, Sigmar Schnutenhaus, Holger Schön, Andreas Schulte, Nelly Schulz-Weidner, Karola Schulze, Ralf Schulze, Falk Schwendicke, Thomas A. Schwenk, Andreas Simka, Ralf Smeets, Önder Solakoglu, David Sonntag, Hansmartin Spatzier, Benedikt Spies, Norbert Staab, Sabine Steding, Angela Stillhart, Marcus Stoetzer, Hendrik Terheyden, Andrea Thumeyer, Marin Vodanovic, Kai Voß, Maximilian Voß, Wolfgang Wahlster, Michael Walter, Sandra Weber, Almut Johanna Weigel, Paul Weigl, Michael Weiss, Hans-Jürgen Wenz, Johannes-Simon Wenzler, Christian Wesemann, Jens Westemeier, Lotta Westphal, Matthias Widbiller, Annette Wiegand, Horst Willeweit, Karl Frederick Wilms, Sandra Windecker, Michael M. Wolf, Anne Wolowski, Bernd Wöstmann, Sylvia Wuttig
Quintessenz Verlags-GmbH
Deutscher Zahnärztetag 2018
MISSERFOLGE - erkennen, beherrschen, vermeiden9. Nov 2018 — 10. Nov 2018Congress Center Messe Frankfurt
Speakers: Karl-Ludwig Ackermann, Sarah Al-Maawi, Bilal Al-Nawas, Kurt Werner Alt, Anna Greta Barbe, Tobias Bauer, Daniel Bäumer, Marco Baz Bartels, Grietje Beck, Katrin Bekes, Christoph Benz, Dirk Bleiel, Johannes Boesch, Martin Boost, Wolfgang Buchalla, Oskar Bunz, Fabian Cieplik, Monika Daubländer, Sybille David-Hebgen, Andreas Dehler, Renate Deinzer, Sonja H. M. Derman, Konstanze Diekmeyer, Ingmar Dobberstein, Heike Dyrna, Thomas Eger, Guido Elsäßer, Anne Sophie Engel, Peter Engel, Norbert Enkling, Susanne Fath, Stefan Fickl, Michael Frank, Roland Frankenberger, Rene Franzen, Kerstin Galler, Carolina Ganß, Roland Garve, Christian Ralf Gernhardt, Werner Geurtsen, Shahram Ghanaati, Petra Gierthmühlen, Christiane Gleissner, Werner Götz, Susanne Grässel, Dominik Groß, Stefan Grümer, Claus Grundmann, Martin Guffart, Heinz-Michael Günther, Norbert Gutknecht, Peter Hahner, Elmar Hellwig, Christian Henrici, Katrin Hertrampf, Fabian Huettig, Michael Hülsmann, Bruno Imhoff, Steffani Janko, Holger Jentsch, A. Rainer Jordan, Ana Elisa Kauling, Moritz Kebschull, Christian Kirschneck, Joachim Klimek, Andrea Klink, Thomas Klinke, Birte Koch, Thomas Kocher, Eva Köllensperger, Heike Maria Korbmacher-Steiner, Bernd Kordaß, Hannah Kottmann, Pablo Krämer-Fernandez, Gabriel Krastl, Birgit Krause, Till Kreutzer, Conrad Kühnöl, Stefanie Kurzschenkel, Thorsten Kuypers, Günter Lauer, Hans-Christoph Lauer, Elfi Laurisch, Tina Lawall, Karl Martin Lehmann, Silke Lehmann-Binder M.Sc., Dirk Leisenberg, Ulrike Lübbert, Michael Lüpke, Thomas Malik, Jutta Margraf-Stiksrud, Lorenz Meinel, Gudrun Mentel, Wibke Merten, Louisa Mewes, Johanna Isabel Moosmüller, Martin U. Müller, Wolfgang Müller, Nicole Nicklisch, Ina Nitschke, Michael J. Noack, Marina Nörr-Müller, Karina Obreja, Dietmar Oesterreich, Puria Parvini, Ingrid Peroz, Waldemar Petker, Oksana Petruchin, Andree Piwowarczyk, Peter Pospiech, Peter Proff, Sven Reich, Katharina Reichenmiller, Katharina Reinecke, Bernd Reiss, Svenja Rink, Christiane Rinnen, Jerome Rotgans, Sebastian Ruge, Didem Sahin, Sonja Sälzer, Petra Santander, Heidrun Schaaf, Jürgen Schäffer, Elisabeth Schiffner, Ulrich Schiffner, Markus Schlee, Maximiliane Amelie Schlenz, Peter Schmidt, Andrea-Maria Schmidt-Westhausen, Claas Ole Schmitt, Sigmar Schnutenhaus, Jörg Schröder, Gerd Schröter, Andreas Schulte, Philipp Schwaab, Frank Schwarz, Falk Schwendicke, Clemens Schwerin, Sinan Sen, Önder Solakoglu, Hansmartin Spatzier, Christian H. Splieth, Norbert Staab, Bernd Stadlinger, Sabine Steding, Marcus Stoetzer, Giorgio Tabanella, Gisela Tascher, Hendrik Terheyden, Valentina A. Tesky, Jan Tetsch, Juliane von Hoyningen-Huene, Maximilian Voß, Michael Walter, Alexander Welk, Dietmar Weng, Hans-Jürgen Wenz, Jens Westemeier, Lotta Westphal, Annette Wiegand, Karl Frederick Wilms, Michael M. Wolf, Diana Wolff, Anne Wolowski, Johann-Dietrich Wörner, Sylvia Wuttig, Mohamed Younis, Stefan Zimmer, Lisa Zumpe
Quintessenz Verlags-GmbH
This author's journal articles
QZ - Quintessenz Zahntechnik, 12/2021
Auf ein WortPages 1422-1423, Language: GermanPospiech, Peter
Bewährtes Verfahren zur Bestimmung der zentrischen Kieferrelation
Stütz- beziehungsweise Pfeilwinkelregistrate sind eine seit über 100 Jahren bewährte Methode, den Unterkiefer in eine austarierte Position zu bringen. Dennoch schrecken noch viele Behandler davor zurück, sie anzuwenden. Der Beitrag beschreibt die Vorgehensweise und die Vorteile einer elektronischen Pfeilwinkelaufzeichnung.
Keywords: Stützstiftregistrat, Kieferrelation, Zentrikregistrat, Schreibplatte, Registrierschablone
Purpose: This study aimed to compare the long-term outcomes of two different nonimplant treatments in the bilateral shortened dental arch (SDA).
Materials and Methods: In a multicenter randomized controlled clinical trial, patients with complete molar loss in one arch were assigned to one of two different nonimplant treatments. In the partial removable dental prosthesis (PRDP) group, patients were provided with a distal-extension prosthesis retained with precision attachments. In the SDA group, patients were treated according to the SDA concept by preserving or restoring a premolar occlusion.
Results: Of the 152 treated patients, 82 reached the 10-year examination independent of their dental or prosthetic status. In the intention-to-treat analysis, the survival rates for tooth loss at 10 years were 0.44 (95% confidence interval [CI]: 0.30 to 0.56) in the PRDP group and 0.52 (95% CI: 0.37 to 0.65) in the SDA group. For tooth loss in the study arch, the survival rates were 0.67 (95% CI: 0.52 to 0.78) in the PRDP group and 0.60 (95% CI: 0.45 to 0.73) in the SDA group. The number of teeth lost was higher than expected. In a multivariate analysis using a multiple Cox regression model, the covariates age (unit: 1 year, Hazard Ratio [HR]: 1.033, P = .03) and DMFT value (unit: 1 tooth, HR: 1.121, P = .03) were significant for time to first tooth loss in the study arch.
Conclusion: The results suggest an overestimation of the influence of the prosthetic management of the bilateral SDA. In treatment decisions, patient preferences should be considered with appropriate weight.
Während festsitzender Zahnersatz schon seit Jahren vollständig bzw. teilweise digital hergestellt werden kann, steht der herausnehmbare Zahnersatz erst am Beginn dieser Entwicklung. In der Totalprothetik scheinen sich bereits gangbare und klinikreife Wege abzuzeichnen. Die hinsichtlich Konstruktion, Planung und Ausführung komplexeren Anforderungen der Teilprothese erlauben bislang allerdings keine rein digitalen Lösungen. Hier sind auch die Möglichkeiten einer rechnergestützten Planung noch nicht ausgeschöpft. Neue Materialkombinationen, Rapid-Prototyping-Verfahren und CAD-Konstruktionen gibt es zwar schon in Ansätzen, aber die Serienreife lässt noch auf sich warten.
Keywords: CAD/CAM, Teilprothese, Laserschmelzen, Einstückgerüstprothese, Monoframe-Prothese
International Journal of Computerized Dentistry, 4/2017
PubMed ID (PMID): 29292411Pages 363-375, Language: English, GermanRobben, Jan / Muallah, Jonas / Wesemann, Christian / Nowak, Roxana / Mah, James / Pospiech, Peter / Bumann, Axel
Plaster casts can be digitized with desktop scanners, intraoral scanners, and recently also with cone beam computed tomography (CBCT). The aim of this study was to investigate the accuracy of five different CBCT devices digitizing a plaster cast. A study cast serving as a patient was made using the double mix impression technique, and the impression was poured out with plaster. On the resulting plaster cast, arch length (AL), intermolar width (IMW), and intercanine width (ICW) were measured by a coordinate measuring machine (CMM) (Zeiss O-Inspect 422). The patient cast was then scanned by five CBCT devices - CS 9300, CS 9300 Select, CS 8100 3D (all Carestream), Promax 3D Mid (Planmeca), and Whitefox (Acteon) - in eight scan modes. For each CBCT device, 37 scans were performed. The resulting DICOM data were exported as stereolithographic (STL) data and linearly measured using Convince Premium 2012 (3Shape) software. All measurements were compared to the reference master values of the patient cast. The accuracy measurements showed significant differences among the CBCT devices. The highest accuracy was achieved by Whitefox (IMW: mean ± standard deviation (SD): 5.5 ± 5.7 µm) and CS 9300 (IMW: -15 ± 7.4 µm). Comparable results with less accuracy were shown by CS 8100 3D (IMW: -81.2 ± 7.4 µm) and CS 300 Select (IMW: -82.2 ± 6.6 µm). Significantly lower accuracy was shown by Promax 3D Mid (IMW: -126.1 ± 4.8 µm). Some CBCT devices are suitable for the digitization of plaster casts and show very good clinical accuracy. Dental offices equipped with CBCT devices could digitize plaster casts without the need for additional devices.
Keywords: CBCT devices, accuracy, indirect digitization, plaster cast, CAD/CAM, stereolithography
International Journal of Computerized Dentistry, 2/2017
PubMed ID (PMID): 28630956Pages 151-164, Language: English, GermanMuallah, Jonas / Wesemann, Christian / Nowak, Roxana / Robben, Jan / Mah, James / Pospiech, Peter / Bumann, Axel
The aim of this study was to compare the accuracy of six intraoral scanners as regards clinically relevant distances using a new method of evaluation. An additional objective was to compare intraoral scanners with the indirect digitization of model scanners. A resin master model was created by 3D printing and drilled in five places to reflect the following distances: intermolar width (IMW), intercanine width (ICW), and arch length (AL). To determine a gold standard, the distances were measured with a coordinate measuring instrument (Zeiss O-Inspect 422). The master model was scanned 37 times with the following intraoral scanners: Apollo DI (Sirona), CS 3500 (Carestream Dental), iTero (Cadent), PlanScan (Planmeca), Trios (3Shape), and True Definition (3M Espe), and indirectly digitized with the OrthoX Scan (Dentaurum). The digital models were then measured, and deviations from the gold standard calculated. Significant differences were found between the devices. Among the intraoral scanners, Trios and iTero showed the most accurate results, although CS 3500, True Definition, and Apollo DI achieved comparable results. PlanScan demonstrated the highest deviations from the gold standard, and presented a high standard deviation (SD). Direct digitization revealed comparable (and, in fact, slightly higher) accuracy than indirect digitization. Both indirect digitization and most of the intraoral scanners were therefore demonstrated to be suitable for use in the orthodontic office, with the exception of PlanScan, which did not meet the demands of individual orthodontic treatment.
Keywords: intraoral scanner, indirect digitization, full-arch scan, digital impression, CAD/CAM, accuracy
The International Journal of Oral & Maxillofacial Implants, 5/2010
PubMed ID (PMID): 20862414Pages 991-998, Language: EnglishNothdurft, Frank P. / Doppler, Klaus E. / Erdelt, Kurt J. / Knauber, Andreas W. / Pospiech, Peter R.
Purpose: The aim of the study was to evaluate the influence of artificial aging on the fracture behavior of straight and angulated zirconia implant abutments used in ZirDesign (Astra Tech) implant/tooth-supported fixed partial dentures (FPDs) in the maxilla.
Materials and Methods: Four different test groups (n = 8) representing anterior implant/tooth-supported FPDs were prepared. Groups 1 and 2 simulated a clinical situation with an ideal implant position (maxillary left central incisor) from a prosthetic point of view, which allowed for the use of a straight, prefabricated zirconia abutment. Groups 3 and 4 simulated a situation with a compromised implant position that required an angulated (20-degree) abutment. OsseoSpeed implants (4.5 3 13 mm, Astra Tech) as well as metal tooth analogs (maxillary right lateral incisor) with simulated periodontal mobility were mounted in polymethyl methacrylate. The FPDs (chromium-cobalt alloy) were cemented with glass ionomer. Groups 2 and 4 were thermomechanically loaded and subjected to static loading until failure. Statistical analysis of force data at the fracture site was performed using nonparametric tests.
Results: All samples survived thermomechanical loading. Artificial aging did not lead to a significant decrease in load-bearing capacity in either the straight abutments or the angulated abutments. The restorations that used angulated abutments exhibited higher fracture loads than the restorations with straight abutments (group 1: 209.13 ± 39.11 N; group 2: 233.63 ± 30.68 N; group 3: 324.62 ± 108.07 N; group 4: 361.75 ± 73.82 N). This difference in load-bearing performance was statistically significant, both with and without artificial aging. All abutment fractures occurred below the implant shoulder.
Conclusions: Compensation for angulated implant positions with an angulated zirconia abutment is possible without reducing the load-bearing capacity of implant/tooth-supported anterior FPDs.
Keywords: fatigue testing, fracture resistance, implant abutments, load-bearing capability, zirconia, zirconium dioxide