Dr. Tomas Linkevicius has received DDS degree in 2000 in Kaunas University, Lithuania. In 2004 he finished post-graduate program in prosthodontics in Vilnius University. In 2009 he has defended theses “The influence of mucosal tissue thickness on crestal bone stability around dental implants” and received PhD degree in Riga Stradins University, Latvia. Currently, dr. Tomas Linkevicius serves as Assoc. Professor in Institute of Odontology, Vilnius University. He also works in private practice “Vilnius Implantology Center” and is a founder of private research center “Vilnius Research Group”. Dr. Tomas Linkevicius serves as a reviewer in dental journals, like “International Journal of Oral and Maxillofacial Implants”, “Journal of Periodontology”, “Clinical Implant Dentistry and Related Research” and “Journal of Clinical Periodontology”. He is the author and co-author of many articles in international journals, indexed in PubMed.
1st Edition 2019 Book Hardcover, 21,6 x 27,9 cm, 304 pages, 1231 illus Language: English Categories: Implantology, Oral Surgery Stock No.: 7619 ISBN 978-0-86715-799-4 QP USA
15.06.2022 — 18.06.2022Bella Center Copenhagen, Copenhagen, Denmark
Speakers: Mario Aimetti, Zvi Artzi, Serhat Aslan, Georgios Belibasakis, Florian Beuer, Juan Blanco Carrión, Michael M. Bornstein, Nagihan Bostanci, Philippe Bouchard, Darko Božić, Francesco Cairo, Olivier Carcuac, Maria Clotilde Carra, Nelson Carranza, Iain L. C. Chapple, Pierpaolo Cortellini, Jan Cosyn, Mike Curtis, Francesco D'Aiuto, Bettina Dannewitz, Massimo De Sanctis, Luca De Stavola, Jan Derks, Nikolaos Donos, Peter Eickholz, Bahar Eren Kuru, Ricardo Faria Almeida, Roberto Farina, Magda Feres, Elena Figuero, Dagmar Fosså Bunæs, Rok Gašperšič, William Giannobile, Cecilie Gjerde Gjengedal, Moshe Goldstein, Marjolaine Gosset, Klaus Gotfredsen, Filippo Graziani, Adrian Guerrero, George Hajishengallis, Hady Haririan, Lisa J. A. Heitz-Mayfield, Palle Holmstrup, Markus B. Hürzeler, Mark Ide, Søren Jepsen, Ronald E. Jung, Sérgio Kahn, Anhgela R. Kamer, Alpdogan Kantarci, Moritz Kebschull, Björn Klinge, Thomas Kocher, Odd Carsten Koldsland, Kenneth Kornman, Purnima Kumar, Marja Laine, Markus Laky, Isabelle Laleman, Evanthia Lalla, France Lambert, Luca Landi, Niklaus P. Lang, Antonio Liñares, Tomas Linkevičius, Bruno Loos, Rodrigo Lopez, Eli Machtei, Aslan Mammadov, Mauro Merli, Andrea Mombelli, Eduardo Montero, Niki Moutsopoulos, Jose Nart, Gustavo G. Nascimento, Ian Needleman, Tiernan O'Brien, William Papaioannou, Panos N. Papapanou, Michael A. Pikos, Pawel Plakwicz, Constanza Pontarolo, Philip M. Preshaw, Marc Quirynen, Mia Rakic, Christoph Andreas Ramseier, Hélène Rangé, Papageorgiou Spyridon, Maurizio S. Tonetti, Leonardo Trombelli, Istvan Urban, Fridus van der Weijden, Fabio Vignoletti, Charalambos Vlachopoulos, Nicola West, Asaf Wilensky, Ion Zabalegui, Egija Zaura, Nicola Zitzmann, Giovanni Zucchelli, Otto Zuhr, Fardal Øystein
European Federation of Periodontology (EFP)
Quintessence Live Aid
Quintessential Speakers from around the world offer a Day of Education that will help those in need29.04.2022Zoom
Speakers: Wael Att, Maxim Belograd, Victor Clavijo, Christian Coachman, Stefan Fickl, Ronaldo Hirata, Fouad Khoury, Tomas Linkevičius, Pascal Magne, Nazariy Mykhaylyuk, José M. Navarro, Irena Sailer, Anton Sculean, Kyle Stanley, Miguel Stanley, Markus Tröltzsch, Istvan Urban, Débora R. Vilaboa, Giovanni Zucchelli, Otto Zuhr
sold outQuintessenz Verlags-GmbH
40th Congresso Internazionale
La rivoluzione protesica: cosa è cambiato, cosa è ancora attuale18.11.2021 — 20.11.2021Palazzo dei Congressi Bologna, Bologna, Italy
Speakers: Ingo Baresel, Florian Beuer, Cristiano Broseghini, Mauro Broseghini, Gaetano Calesini, Roberto Canalis, Davide Cortellini, Marco Degidi, Stefano Gracis, Stefano Granata, Bernd Kordaß, Tomas Linkevičius, Ignazio Loi, Paolo Miceli, Ricardo Mitrani, Nazariy Mykhaylyuk, Piotr Nagadowsky, José M. Navarro, Jan Schünemann, Clemens Schwerin, Lorenzo Trevisiol, Luca Vailati, Marco Valenti, Naoto Yuasa
Accademia Italiana di Odontoiatria Protesica (AIOP)
EAO Digital Days
Implantology: Beyond your expectations12.10.2021 — 14.10.2021online
Speakers: Enrico Agliardi, Alessandro Agnini, Andrea Agnini, Mauricio Araujo, Goran Benic, Juan Blanco Carrión, Daniel Buser, Francesco Cairo, Raffaele Cavalcanti, Tali Chackartchi, Luca Cordaro, Jan Cosyn, Holger Essig, Vincent Fehmer, Stefan Fickl, Alberto Fonzar, Helena Francisco, German O. Gallucci, Ramin Gomez-Meda, Oscar Gonzalez-Martin, Robert Haas, Arndt Happe, Alexis Ioannidis, Ronald E. Jung, Niklaus P. Lang, Tomas Linkevičius, Iva Milinkovic, Sven Mühlemann, Katja Nelson, Sergio Piano, Michael A. Pikos, Bjarni E. Pjetursson, Marc Quirynen, Franck Renouard, Isabella Rocchietta, Dennis Rohner, Irena Sailer, Henning Schliephake, Shakeel Shahdad, Massimo Simion, Ali Tahmaseb, Hendrik Terheyden, Jochen Tunkel, Stefan Vandeweghe, Piero Venezia, Stijn Vervaeke, Martin Wanendeya, Georg Watzek, Giovanni Zucchelli
European Association for Osseintegration (EAO)
This author's journal articles
The International Journal of Oral & Maxillofacial Implants, 2/2022
DOI: 10.11607/jomi.9406Pages 320-327, Language: EnglishLinkevicius, Tomas / Alkimavicius, Jonas / Linkevicius, Rokas / Gineviciute, Evelina / Linkeviciene, Laura
Purpose: To determine the effect of 0.7- and 2.4-mm transmucosal abutment height titanium bases on the crestal bone stability and peri-implant soft tissue condition of bone-level implants with platform switching in patients with vertically thick soft tissues.
Materials and methods: Sixty bone-level platform-switched implants were placed in the molar and premolar regions of both arches in 60 patients. All epicrestally inserted nonsubmerged implants had a 4.1-mm diameter and, after osteointegration, were randomly allocated into two groups: (1) the short group, with a titanium base of 0.7-mm transmucosal abutment height, and (2) the high group with a 2.4-mm height. Monolithic zirconia restorations were fabricated for all implants. Parallel intraoral radiographs were obtained after the delivery of restorations (T1) and after 1 year (T2). Crestal bone levels and peri-implant soft tissue conditions were calculated for each implant. The significance level was set at α = .05.
Results: After 1 year, 55 patients were evaluated, with a mean bone loss of 0.6 ± 0.51 mm (median: 0.71, range: 0 to 2.09 mm) in the short group (23 patients) and 0.45 ± 0.59 mm (median: 0.65, range: 0 to 2.12 mm) in the high group (22 patients), showing no significant difference between groups (P = .168). A significant increase in marginal bone height was noted between the T1 and T2 time points in the short and high (P = .029 and .001, respectively) groups. The peri-implant soft tissue health parameters did not show statistically significant differences.
Conclusion: Crestal bone stability after 1 year of follow-up around epicrestally placed platform-switched implants is not influenced by transmucosal abutment height, if the vertical soft tissue thickness is ≥ 3 mm.
Keywords: prosthodontics, randomized controlled clinical trial, single implant
International Journal of Periodontics & Restorative Dentistry, 3/2021
Pages 347-355, Language: EnglishZukauskas, Saulius / Puisys, Algirdas / Andrijauskas, Paulius / Zaleckas, Linas / Vindasiute-Narbute, Egle / Linkevičius, Tomas
This case control study measured early crestal bone changes around subcrestally placed platform-switched implants surrounded by thin soft tissue and compared them with regular, matching-platform implants placed in a supracrestal position and surrounded by thick soft tissue. Sixty-six patients received two-piece internal hex dental implants. Control group patients (n = 33) received implants that had a horizontally matching implant-abutment connection and were placed approximately 0.5 to 1 mm supracrestally. Test group patients (n = 33) received platform-switched implants that were placed about 1.5 mm subcrestally. Clinical examinations were conducted, intraoral radiographs were taken, and statistical analysis was performed. After 2 months, the mean bone loss was 0.2 mm (SD: 0.22 mm; range: 0.1 to 1.2 mm) in the control group and –0.69 mm (SD: 0.65 mm; range: 0 to 2.6 mm) in the test group; this difference was found to be statistically significant (P < .05). After 1 year, mean bone loss was 0.28 mm (SD: 0.36 mm; range: 0.1 to 1.63 mm) in the control group and –0.6 mm (SD: 0.55 mm; range: 0.05 to 1.8 mm) in the test group. Platform-switched implants placed in a subcrestal position in vertically thin soft tissues showed statistically significantly more bone loss than non–platformswitched implants placed supracrestally with vertically thick tissues.
Purpose: The purpose of this study was to survey practicing clinicians and determine if differences existed concerning their use of torque-limiting devices (TLDs) and screw-tightening protocols, comparing this with existing universal industry standards.
Materials and methods: A nine-question survey was administered with 428 dentists providing data for three specific areas: (1) demographic information-TLD ownership, device age, frequency of use, and observations of screw loosening; (2) recognition information-calibration, reading measurements of the TLD, and the meaning of preload; (3) usage information-screw-tightening protocols and effect of speed during actioning of the TLD. Data collection was compared with industry standards for use of hand torque tools including ISO-6789 1,2:2017 and related texts pertaining to screw fastener protocols.
Results: The beam-type TLD was the most popular; however, 33% surveyed used it incorrectly. Most TLDs being used were older than 1 year, with only 6% calibrated. Forty-eight percent observed screw loosening less than once per year, while 44% reported three or more occurrences per year. A similar number used the TLD for implant placement and abutment screw tightening. Screw-tightening protocols varied. Preload was not understood by the majority of those surveyed.
Conclusion: Dentistry does not appear to adhere to the protocols and standards recommended by other industries that also rely on screw-fastening mechanisms and TLDs. Further education and training appears to be warranted in this area of implant dentistry to reduce the risks of screw-associated complications.
Keywords: abutment screw loosening, calibration, implant screws, preload, screw-tightening, torque-limiting device
The International Journal of Prosthodontics, 2/2020
DOI: 10.11607/ijp.6686, PubMed ID (PMID): 32069347Pages 217-223, Language: EnglishLinkevicius, Tomas / Valantiejiene, Valda / Alkimavicius, Jonas / Gineviciute, Evelina / Andrijauskas, Rolandas / Linkeviciene, Laura
Purpose: To evaluate the surface roughness values of zirconium oxide samples that were gradually polished using a commercially available polishing system and polishing paste.
Materials and Methods: A total of 50 rectangular specimens of predetermined size (10 × 10 × 3 mm) were sintered from zirconium oxide. Samples were randomly assigned to one of five groups (n = 10 each): control, coarse (Co), fine (F), super fine (SF), or polishing paste (PP). In the control group, no polishing was done; in the Co group, a coarse polisher was used; and the specimens in the remaining three groups underwent additional processing with a fine rubber abrasive. For SF and PP samples, subsequent treatment with a super fine polisher was applied. Finally, for the PP group, a goat-hair brush with diamond polishing paste was used. An optical profilometer was used to evaluate roughness average (Ra) in micrometers (μm). ANOVA and Games-Howell post hoc tests were utilized to detect differences between groups. The significance level was set to α = .05.
Results: Surface roughness gradually decreased with further polishing throughout the groups: control Ra = 0.525 ± 0.099 μm; Co Ra = 0.252 ± 0.038 μm; F Ra = 0.196 ± 0.035 μm; SF Ra = 0.114 ± 0.031 μm; and PP Ra = 0.054 ± 0.020 μm. Statistically significant differences were detected among all groups (P < .05).
Conclusion: A surface roughness of 0.054 μm can be achieved if a full zirconia polishing protocol is used. Zirconium oxide can be polished to various surface roughnesses using commercially available polishing products.
International Journal of Periodontics & Restorative Dentistry, 3/2019
DOI: 10.11607/prd.4097, PubMed ID (PMID): 30986283Pages 341-347, Language: EnglishPuisys, Algirdas / Zukauskas, Saulius / Kubilius, Ricardas / Barbeck, Mike / Razukevičius, Dainius / Linkevičiene, Laura / Linkevičius, Tomas
This case series aimed to clinically and histologically evaluate porcine-derived membrane used for vertical thickening of thin soft tissues. Twenty porcinederived collagen membranes and bone-level implants were placed in 20 patients. After 2 months, thickened soft tissues were measured and biopsy samples were harvested. All xenografts healed successfully. The average thickness of thin soft tissue before vertical thickening was 1.65 ± 0.36 mm, while tissue thickness increased to 3.45 ± 0.52 mm after the procedure (P < .001); the mean thickness increase was 1.8 ± 0.13 mm. Histologic analysis showed complete integration of the graft and no differences (P = .4578) in vascularization between the host (39.74 ± 17.15 vessels/mm2) and graft (30.43 ± 11.26 vessels/mm2). It can be concluded that porcine-derived membrane can be used for vertical soft tissue thickening with substantial gain in tissue height.
Current use of zirconium oxide (ZrO₂)-based screw-retained restorations does not guarantee maximum contact of soft peri-implant tissues with ZrO₂, because veneering porcelain usually covers the major subgingival part of the restoration. Ceramics preclude direct interaction between zirconia and soft tissue cells, thus reducing biocompatibility and benefit to the patient. The four case reports discussed in this article describe the new design modality of the ZrO₂ screwretained restorations, in which zirconia is exposed to the tissues and no veneering porcelain is located below the gingival margin. The article also shows the impact of this treatment on soft peri-implant tissues after 3 years of follow-up. Soft tissue recession, vestibular contour, bleeding on probing, and probing depth were evaluated.
Purpose: The aim of this clinical trial was to evaluate the influence of gingival tissue thickness on crestal bone loss around dental implants after a 1-year follow-up.
Materials and Methods: Forty-six implants (23 test and 23 control) were placed in 19 patients. The test implants were placed about 2 mm supracrestally, whereas the control implants were positioned at the bone level. Before implant placement, the tissue thickness at implant sites was measured with a periodontal probe. After healing, metal-ceramic cement-retained prostheses were constructed. According to tissue thickness, the test implants were divided into A (thin) and B (thick) groups. Intraoral radiographs were performed and crestal bone changes were measured at implant placement and after 1 year.
Results: Mean bone loss around the test implants in group A (thin mucosa) was 1.61 ± 0.24 mm (SE; range, 0.9 to 3.3 mm) on the mesial and 1.28 ± 0.167 mm (range, 0.8 to 2.1 mm) on the distal. Mean bone loss in test group B (thick mucosa) implants was 0.26 ± 0.08 mm (range, 0.2 to 0.9 mm) on the mesial aspect and 0.09 ± 0.05 mm (range, 0.2 to 0.6 mm) on the distal aspect. Mean bone loss around control implants was 1.8 ± 0.164 mm (range, 0.6 to 4.0 mm) and 1.87 ± 0.166 mm (range, 0.0 to 4.1 mm) on the mesial and distal aspects, respectively. Analysis of variance revealed a significant difference in terms of bone loss between test A (thin) and B (thick) groups on both the mesial and the distal.
Conclusion: Initial gingival tissue thickness at the crest may be considered as a significant influence on marginal bone stability around implants. If the tissue thickness is 2.0 mm or less, crestal bone loss up to 1.45 mm may occur, despite a supracrestal position of the implant-abutment interface.
Keywords: biologic width, crestal bone loss, dental implants, microgap, mucosal thickness
Purpose: The aim of this systematic review was to evaluate available evidence for a difference in the stability of peri-implant tissues between titanium abutments versus gold alloy, zirconium oxide, or aluminum oxide abutments.
Materials and Methods: Studies were identified by examining several electronic databases and major dental implant, prosthetic, and periodontal journals. To be selected for the preliminary article pool, the article must have been written in the English language and published from 1980 to March 2007. Articles were sorted based on the nature of the study. In vitro studies and literature reviews were excluded. The included articles were clinical, human histology, and animal studies. Case reports, case series, uncontrolled clinical trials, and clinical studies with teeth treated as a control were excluded from the final review.
Results: The initial article pool included 40 articles of which 9 met the inclusion criteria: 3 animal studies, 2 human histological studies, and 4 randomized clinical trials. Soft tissue recession was not accurately measured in the included clinical studies. Assessment of peri-implant tissues around zirconium oxide and titanium abutments was described only in animal and human histologic studies. Due to differences in study types, timing of follow-ups, and outcome variables, meta-analysis could not be performed.
Conclusions: Included studies revealed that titanium abutments did not maintain a higher bone level in comparison to gold alloy, aluminum oxide, or zirconium oxide abutments. However, there is a lack of information about the clinical performance of zirconium oxide and gold alloy abutments as compared to titanium abutments.
Keywords: abutment, aluminum, biologic width, crestal bone loss, gold alloy, implant, peri-implant soft tissues, zirconium