Purpose: To evaluate implant osseointegration in grafted autogenous bone blocks fixed with cyanoacrylate-based adhesive and screws. Also, grafted bone fixed either with an adhesive or screw was evaluated.
Materials and methods: Two surgical defects in the parietal region of rabbits (n = 12) were performed in each animal. Autogenous bone blocks obtained were fixed anteriorly with a screw or cyanoacrylate-based adhesive. After 30 and 45 days of grafting procedures, implants were placed in bone blocks. Histomorphometric and microcomputed tomography (micro-CT) analyses of the implant area were performed at 30 days after implant surgery in the screw (n = 6) and adhesive (n = 6) groups. Histomorphometric analyses of bone-grafted areas were performed at 60 and 75 days in the screw (n = 6) and adhesive (n = 6) groups. Histomorphometric evaluations were carried out in implant and grafted bone areas. The micro-CT parameters evaluated were bone-to-implant contact, bone area fraction occupancy, bone volume fraction, trabecular thickness, trabecular separation, and trabecular number.
Results: No differences were observed in the micro-CT parameters for the screw and adhesive groups in all experimental periods. However, an increased quantity of immature bone volume was observed on the adhesive group in the grafted area after 75 days. The grafted area in the screw group (75 days) presented a decrease in the volume density of the immature bone compared with the screw group (60 days). There were no differences in both groups and experimental periods in soft tissue in the grafted area.
Conclusion: No differences were observed in the osseointegration of implants placed in grafted autogenous bone blocks fixed with cyanoacrylate-based adhesive and screws. Therefore, osseointegration in autogenous bone fixed with cyanoacrylate-based adhesive is viable.
Schlagwörter: bone remodeling, bone transplantation, cyanoacrylates, dental implants, osseointegration